Data centre electrical design

More megawatts from the site you already have.

Senior electrical design for data centres, from grid connection to rack. Feasibility, design and studies for operators adding AI density, extending capacity or cutting energy use without risking uptime.

Simplified single-line diagram: grid, transformer, switchgear, UPS, racks GRID132 kV TX132/11 kV 11 kV BUS UPS A UPS B 400 V
SLD-001 · TYPICAL 2N ARRANGEMENTNTS
Voltage levels132 kV → 400 V
ResilienceN+1 · 2N
Rack densityAir to liquid
PUE roadmaps1.60 → 1.30
Services by RIBA stage

From first assessment to signed-off design

Work is scoped as a fixed-fee package or as an interim lead inside your team. Each stage stands on its own, so you can start with feasibility and decide from there.

RIBA 1–2

Feasibility

Existing-site power and capacity assessment, HV/LV topology options, UPS strategy appraisal, energy analysis from metered data, CAPEX benchmarks and a PUE roadmap.

RIBA 3–4

Concept and developed design

Single-line diagrams, N+1 and 2N architecture, liquid-cooling power integration, generator and UPS sizing, switchgear and distribution board schedules.

Any stage

Electrical studies

Load flow, fault level, discrimination and arc flash studies, with labelling and settings recommendations.

Any stage

Grid and energy

Grid connection support, capacity planning, flexibility and load-shifting options, and heat reuse appraisal.

Fixed term

Interim electrical lead

Design lead or design-review role inside your team or consultancy, for a defined period.

Experience

Work where uptime and assurance come first

Projects are described without client names. References are available on request, with client consent.

European colocation data centre

Feasibility for a capacity and efficiency upgrade

Infrastructure assessment, UPS scenario appraisal, energy analysis from 12 months of metered data, CAPEX benchmarks, HV/LV topology, liquid-cooling architecture and arc flash studies.

PUE 1.601.30 by 2030
High-integrity UK infrastructure

Lead and principal electrical roles on nuclear and naval sites

Design under safety, resilience and assurance standards well above typical commercial work. The same discipline carries into mission-critical data centres.

Deliverables

Documents clients can act on

Technical design guides, equipment schedules, study reports and board-level presentations built for decisions, not shelf space.

Project scoper

Scope your project in a minute

Answer five questions to see the recommended package and a typical programme. Then send it with the form below, or copy it into an email.

What are you planning?
12 MW
Where are you now?
Resilience target
Location
Recommended packageREF —

Feasibility study

4–6 weekstypical programme, confirmed after a scoping call
Deliverables
    Your enquiry, ready to send
    
                  
    Then email it to lltconsultancyltd@gmail.com
    Send your enquiry

    Send it straight to Lee

    Your scoped enquiry is filled in below. Add your details and send. You'll get a reply within two working days.

    Your details are used only to reply to this enquiry.
    Insights

    Energy, the grid and AI's power demand, explained

    Short videos that check the claims in the news against the numbers: data centre power use, grid connection queues and who pays for the build-out.

    Watch on YouTube
    Contact

    Start with a 30-minute scoping call

    Tell me the site, the stage and what you need to decide. You'll get a written fee proposal within five working days.

    Principal
    Lee Thomas, lead electrical design engineer
    Company
    LLT Consultancy Ltd
    Fees
    Fixed fee per package, or day rate for interim roles
    Coverage
    UK and Europe; remote by default, site visits as needed